<?xml version="1.0" encoding="UTF-8" ?>
<modsCollection xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://www.loc.gov/mods/v3" xmlns:slims="http://slims.web.id" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-3.xsd">
<mods version="3.3" ID="17027">
<titleInfo>
<title>Design Of Fluid Leveling Based On Internet Of Things In Continuous Settling Tank</title>
</titleInfo>
<name type="Personal Name" authority="">
<namePart>Ridoy Naldo Simaibang</namePart>
<role><roleTerm type="text">Primary Author</roleTerm></role>
</name>
<name type="Personal Name" authority="">
<namePart>Dr. Ir. Hermantoro, MS. IPU (P)</namePart>
<role><roleTerm type="text">Primary Author</roleTerm></role>
</name>
<name type="Personal Name" authority="">
<namePart>Rengga Arnalis Renjani, S.TP, M. Si, IPM</namePart>
<role><roleTerm type="text">Primary Author</roleTerm></role>
</name>
<typeOfResource manuscript="yes" collection="yes">mixed material</typeOfResource>
<genre authority="marcgt">bibliography</genre>
<originInfo>
<place><placeTerm type="text">yogyakarta</placeTerm></place>
<publisher>INSTIPER</publisher>
<dateIssued>2021</dateIssued>
<issuance>monographic</issuance>
<edition></edition>
</originInfo>
<language>
<languageTerm type="code"></languageTerm>
<languageTerm type="text"></languageTerm>
</language>
<physicalDescription>
<form authority="gmd">Text</form>
<extent></extent>
</physicalDescription>
<note>Almost more than 600 mills in Indonesia measure the height or leveling of clean CPO at the Continuous Settling Tank used stick sounding.  Conventional monitoring of CPO leveling in CST, only look at sight glass with guessed thickness figures obtained.  The weakness of the sigth glass is that it can’t measure the level of water, and sludge and is very difficult to clean, this makes it difficult for the operator to adjust the oil content that was flowed in the CST underflow.
There are some purpose of writing this paper i.e: design sensor levelling for oil, water, and sludge on CST through a hydrostatic approach that was integrated with the internet or IoT system, measure or detect the level of oil, water and sludge in the CST tank with the IoT system. The method used in this research was to determine as well as test the design and observe the accuracy of the read of the fluid level.
The resulted of this study were the calibration of the upper and lower temperature sensors with a thermocouple, upper temperature sensor R2 = 0,9999, and lower temperature sensor R2 = 1. Calibration of the proximity sensor with a ruler, oil sensor R2 = 0,9994, water sensor R2 = 0,9993, and the sludge sensor R2 = 0,9998.  Succeeded in making a smart CST application that has a volume display of oil, water, sludge in the tank and a graph display of the volume and level of oil, water and sludge.

Keywords : Crude Palm Oil, Continous Settling Tank, Fluid Leveling, Internet of Things, Sensor.</note>
<subject authority=""><topic>ACEH INTERNATIONAL JOURNAL OF SCIENCE AND TECHNOLO</topic></subject>
<subject authority=""><topic>19345</topic></subject>
<subject authority=""><topic>TP-APRIL-2021</topic></subject>
<subject authority=""><topic>SKRIPSI TP 2021</topic></subject>
<subject authority=""><topic>STIK</topic></subject>
<classification>NONE</classification><identifier type="isbn"></identifier><location>
<physicalLocation>Institutional Repository Institut Pertanian STIPER Yogyakarta</physicalLocation>
<shelfLocator></shelfLocator>
<holdingSimple>
<copyInformation>
<numerationAndChronology type="1">APR.2021.UP.TP.015</numerationAndChronology>
<sublocation>My Library</sublocation>
<shelfLocator></shelfLocator>
</copyInformation>
</holdingSimple>
</location>
<slims:digitals>
<slims:digital_item id="41595" url="" path="/14. Surat Hak Kepenulisan_19345.pdf" mimetype="application/pdf">Surat Hak Kepenulisan</slims:digital_item>
<slims:digital_item id="41594" url="" path="/13. Surat Keterangan Publikasi Jurnal_19345.pdf" mimetype="application/pdf">Surat Keterangan Publikasi Jurnal</slims:digital_item>
<slims:digital_item id="41593" url="" path="/12. Surat Pernyataan Publikasi Bermatrai_19345.pdf" mimetype="application/pdf">Surat Pernyataan Publikasi Bermatrai</slims:digital_item>
<slims:digital_item id="41592" url="" path="/11. Ringkasan Skripsi_19345.pdf" mimetype="application/pdf">Ringkasan Skripsi</slims:digital_item>
<slims:digital_item id="41591" url="" path="/10. Abstrak_19345.pdf" mimetype="application/pdf">Abstrak</slims:digital_item>
<slims:digital_item id="41590" url="" path="/9. Daftar Pustaka - Lampiran_19345.pdf" mimetype="application/pdf">Daftar Pustaka - Lampiran</slims:digital_item>
<slims:digital_item id="41589" url="" path="/8. BAB V_19345.pdf" mimetype="application/pdf">BAB V</slims:digital_item>
<slims:digital_item id="41771" url="" path="/BEBAS PUSTAKA_19345.pdf" mimetype="application/pdf">BEBAS PUSTAKA</slims:digital_item>
<slims:digital_item id="41770" url="" path="/JOM_19345.pdf" mimetype="application/pdf">JURNAL</slims:digital_item>
<slims:digital_item id="41584" url="" path="/3. Halaman Pengesahan_19345.pdf" mimetype="application/pdf">Halaman Pengesahan</slims:digital_item>
<slims:digital_item id="41585" url="" path="/4. BAB I_19345.pdf" mimetype="application/pdf">BAB I</slims:digital_item>
<slims:digital_item id="41583" url="" path="/2. Cover - Abstrak_19345.pdf" mimetype="application/pdf">Cover - Abstrak</slims:digital_item>
</slims:digitals><recordInfo>
<recordIdentifier>17027</recordIdentifier>
<recordCreationDate encoding="w3cdtf">2021-04-01 10:50:03</recordCreationDate>
<recordChangeDate encoding="w3cdtf">2021-08-24 08:33:20</recordChangeDate>
<recordOrigin>machine generated</recordOrigin>
</recordInfo></mods></modsCollection>